Wall-Injector - Prevents rising humidity - Aquaplan
COMPLETE KIT : System against rising damp in walls
- containing: 12 injection reservoir tubes, nozzle and connection, 5 L of product, gloves, quick-setting cement,... and instructions for use
For refills 5 or 10+20% free, see the menu below.
Wall-Injector - Prevents rising humidity - Aquaplan
Professional colorless liquid product for injection , with a high percentage of active waterproofing components, used for the definitive treatment of interior and exterior walls against rising damp , above the ground surface.
It forms a lifelong waterproof barrier in the wall, which prevents rising damp from penetrating further and higher.
The Walls-Injection kit contains all the necessary materials:
- 12 reservoir tubes for the product
- 12 PVC injection hoses
- Nozzles to aim
- Quick-setting cement to seal injection holes
- protective glove
- 5 L of Wall-Injection product
5 and 10 + 20% L refills are available separately.
Benefits :
- Protects for life
- The wall remains breathable
- High content of active components
- To be used both indoors and outdoors
Application :
For use in interior and exterior brick walls above grade.
How to protect your wall against rising tides with MUR-INJECTION?
1. How to prepare the substrate?
- Remove baseboards, ceiling and wallpaper.
- Inspect seals and, if necessary, repair to prevent product leaks.
- In a horizontal joint 5 to 7 cm from the floor slab (the thickness of the plinth :-) )
- --> Drill injection holes 10 mm in diameter, spaced 12 cm apart, at an inclination of 10 to 15 degrees.
- --> Drill to a depth of 4/5 of the thickness of the wall.
- For walls thicker than 40 cm, repeat this operation on the other side of the wall.
2. How to use the product?
- Attach the obliquely cut hose to the injection tube via the nozzles
- Place the tubes 50 cm above each drilled hole. NOTE: it is easy to fix the reservoir tubes to a wooden board and keep it 50 cm away (by fixing it to the wall, on wedges, chairs, etc.)
- Push the other end of the flexible pipe to a depth of approximately 2 to 3 cm in the corresponding drilled hole.
- CAUTION: Never place the injection tubes directly into the drilled hole as the distance is necessary for effective penetration of the liquid into the wall.
- Plug the drilled holes by applying quick-setting cement (or putty around the flexible pipe), in order to prevent the product from flowing back.
- If necessary, roughen the flexible pipe by sanding it a little to improve the adhesion of the cement/mastic.
- Fill the injection reservoir tubes and keep them level for 1 hour.
- CAUTION: Thoroughly clean the surfaces in case of splashing and overflow.
- Repeat the treatment after 24 hours.
- 48 hours later the injection is complete.
- Remove the tubes and plug the holes.
YIELD EXAMPLES FOR 1 linear meter:
Consumption :
Approximate example for a classic wall in moderately porous bricks, i.e. 1.5 L per running meter for one meter of wall having a thickness of 10 cm according to the manufacturer's instructions.
For 1 M of wall with a thickness of: |
Consumption (in liters/linear meter) |
---|---|
20cm | +- 3 liters |
25cm | +- 3.75 liters |
30cm | +- 4.5 liters |
35cm | +- 5.25 liters |
40cm | +- 6 liters |
45cm | +- 6.75 liters |
50cm | +- 7.5 liters |
55cm | +- 8.25 liters |
60cm | +- 9 liters |